SETRA 267 Low Pressure

SETRA – Low Differential Pressure Transmitters Model 267   ( Accuracy 0,4%FS )

Accuracy  fino allo 0,25% FS (Non-Linearity, Hysteresis, and Non-Repeatability)

-Compensated Temperature Range ( +5 to +65 °C )

-Operating Temperature Range (-18 to +65 °C )

-Electrical Output  4/20 mA

-Process connection 3/16” Barbed Brass Fitting

-Electrical Termination PG-9 -Maximum Line Pressure 10 PSI

-Supply Voltage (VDC) (minimum ) 9V + 0.02 x (Resistance of Receiver plus line)

( maximum ) 30 V+ 0.004 x (Resistance of Receiver plus line)

-Long-Term Stability 0.1% FS

-IP65/NEMA 4 Plastic Glass-Filled Polycarbonate UL94V-O Case

-Unidirectional o Bidirectional –specificare in base al campo

(     +/- 100 Pa   ) Bidirectional e (     0/+ 1000 Pa ) Unidirectional  IN STOCK

SETRA 267